BlackbodyProviding unique and effective solutions across a variety of industries.

  • IR-574

    2.25" Dia. Cavity

    50°C-1200°C

    The IR-574 Series blackbody reference sources are designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 2.25" Cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allow users to calibrate, align, and measure infrared devices and phenoma of all types.

  • IR-563

    1.0" Dia. Cavity

    50°C-1050°C

    IR-563 is a ideal source for the Near (1-3 um), Mid (3-8) and Far (8-30+ um) infrared bands. The IR-563 has been the industry standard 1000º C blackbody for more than 30 years, and continues to provide excellent service to infrared applications throughout the industry.

  • IR - 564

    1.0" Dia. Cavity

    50°C-1200°C

    The IR-564 extends the temperature range of the IR-563 to 1200 º C by changing cavity materials to Silicon Carbide and high purity Alumina ceramics, otherwise the two units are virtually identical.

  • IR - 704

    0.25" Dia. Cavity

    50°C-1050°C

    IR-704 Multi-Spectral Target System The IR-704 system integrates a Blackbody source, Motorized Aperture wheel, Motorized Filter Wheel, High Speed Shutter and High Speed Filter Shutter. The system was designed as a forced air-cooled Multi-Spectral, Multi-Aperture target system for direct integration with collimator / target projection systems, but can also be used as a direct target system.

  • IR-518

    0.40" Dia. Cavity

    50°C-1050°C

    The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.

  • IR - 519

    0.40" Dia. Cavity

    50°C-1200°C

    The IR-519 Radiation Source extends the temperature range of the IR-518 to 1200ºC. The length of the cavity is extended by 1". It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.

  • IR-508

    0.25" Dia. Cavity

    50°C-1050°C

    The IR-508 blackbody reference source is designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 0.25" cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allows users to calibrate, align, and measure infrared devices and phenomena of all types.